Thermo King Fault Codes

In this table you will find the trouble codes and alarms of the controllers MP-IV, MULTI-TEMP, MP-IV, MP-V, MP-VI, TG-VI, SR-2 and SR-3. Codes recorded by the controller depend on its type, software version, installation model and optional equipment. You will find more detailed information in the table of alarm codes at the facility or in the appropriate operating and diagnostic instructions for the controller.

 

Note. If the alarm code is detected during the installation self-diagnosis, then its number will be preceded by a dash (-).

0

No alarm message

one

Resetting microprocessor power

2

Evaporator coil sensor

3

Return air sensor

four

Charge air control sensor

five

Ambient air sensor

6

Coolant temperature sensor  

7

Engine speed sensor

eight

Installation works by coil sensor

9

High temperature evaporator

ten

High discharge pressure

eleven

Installation is controlled by an alternative sensor.

12

Disconnection due to sensor or digital input

13

Check sensor

14

Defrost timed out

15

Check glow plugs / air inlet heater

sixteen

Manual start not completed

17

Engine does not crank

18

High engine coolant temperature

nineteen

Low engine oil pressure

20

Engine (steam engine   CR )   does not start

21

Check cooling cycle

22

Check heating cycle

23

Cooling cycle malfunction

24

Malfunction heating cycle

25

Check generator

26

Check cooling performance

27

High revs steam engine

28

Interruption of pre-trip check or self-test

29

Defrost damper circuit

thirty

Defrost Closure Jam

31

Oil pressure switch

32

Low cooling performance

33

Check engine speed

34

Modulation circuit

35

Operating relay circuit

36

The motor does not rotate

37

Engine coolant level

38

Phase rotation error

39

Water valve chain

40

High speed chain

41

Check engine coolant temperature

42

Forced installation work at low speed

43

Forced unit operation with low speed modulation

44

Check the fuel system

45

Hot gas bypass valve or hot gas bypass valve circuit

46

Check airflow

47

Trip due to remote sensor

48

Check belts or clutch

49

Check Backup Sensor 1

50

Reset clock

51

Emergency shutdown circuit

52

Heating circuit

53

Economizer valve circuit

54

Test mode timeout

55

Check engine speed

56

Evaporator Fan Speed Low Circuit

57

Circuit of high speed evaporator fan

58

Condenser Fan Low Speed Circuit

59

Condenser Fan High Speed Circuit

60

Booster circuit

61

Low battery voltage check

62

Ammeter out of calibration range

63

Engine or steam engine stopped - cause unknown

64

Pre-trip reminder

65

Abnormal temperature difference

66

Low engine oil level

67

Liquid line solenoid valve

68

Internal controller malfunction

69

Chain of magnetization reversal

70

Crash Timer Fails

71

Interservice counter 4 exceeded the specified time limit

72

Interservice counter 5 exceeds the specified time limit

73

Interservice counter 6 exceeds the specified time limit

74

Reset controller to default settings

75

Malfunction   Ram   controller

76

Malfunction   Controller eeprom

77

Invalid EEPROM Checksum   controller

78

Data logging failed   Eeprom

79

Data Logger Memory Overflow

80

Compressor temperature sensor

81

High temperature compressor

82

Shutdown due to high compressor temperature

83

Low coolant temperature

84

Restart in zero mode

 

85

Forced installation work

86

Discharge Pressure Sensor

87

Suction pressure sensor

88

Reserved for   CR

89

Electronic throttle circuit   ETV

90

Electrical overload

91

Input power availability

92

Sensor Class Not Installed

93

Low suction compressor

94

Loader number 1

95

Loader number   2

96

Low fuel level

97

Remote return air sensor   ( CR )

98

Fuel level sensor

99

High compression ratio compressor

100

Heater Fan Malfunction

101

Temperature control at the evaporator coil outlet   ( CR )

102

Low temperature coil evaporator   ( CR )

103

Low fuel level heater

104

Check the rotational speed of the remote fan (currently not used)

105

The circuit of the electromagnetic valve of pressure in the receiving tank

106

Purge Valve Chain

107

Condenser Intake Solenoid Valve Circuit

108

Opening time limit exceeded

109

High discharge pressure

110

Suction Line Solenoid Valve Circuit

111

Installation configuration

112

Check outboard fans

113

Electric heating circuit

114

Multiple alarms - operation not possible

115

High Pressure Relay

116

ON relay due to high pressure (currently not used)

117

Automatic switching from diesel to electric

118

Automatic switching from electric drive to diesel

119

Reserved for   CR

120

Generator Excitation Circuit

121

Fluid injection circuit

122

Diesel / Electric Drive Relay Circuit

123

Coil Inlet Temperature Sensor

124

Check the evaporator coil outlet temperature sensor

125

Tank level sensor

126

Back pressure regulator

127

Setpoint not set

128

Reminder number 1 on the maintenance of the engine

129

Reminder number 2 on the maintenance of the engine

130

Reminder number 1 on the maintenance of the electric motor

131

Reminder number 2 on the maintenance of the electric motor

132

Reminder number 1 on the maintenance of the total operating time of the installation

133

Reminder number 2 on the maintenance of the total operating time of the installation

134

Power On Time

135

Backup Digital Inputs

136

Backup digital outputs

137

Check the output of the engine heater damper

138

Malfunction of the clock battery of the actual time of the data logger   (DAS )

139

Interrupt Vacuum Mode

140

Currently not used

141

Disabled automatic switching from diesel to electric

142

Check Thermax valve

143

Check the outlet of the remote zone drain hose heater

144

Loss of communication   CAN   in expansion mode

145

Loss of feedback signal on controller

146

Software version mismatch

147

Control at the output of the fan speed   Multi Temp

148

Disable automatic switching from electric drive to diesel

149

Alarm not defined

150

Sensor reading below range   ( DAS and   HMI )

151

Sensor reading over range   ( DAS and   HMI )

152

Faulty sensor   DAS

153

Failed to flash the extension module

154

Malfunction of the shutdown relay due to low suction pressure

155

Loss of communication   CAN   with   HMI

156

Bypass valve suction / heat exchanger fluid

157

Profile mismatch   OptiSet Plus

158

Failed to load the main software.

159

Check battery status

160

Bus loss   CAN   with radio expansion card

161

Malfunction of hours of the actual time of the data recorder   ( DAS )

188

Data logger microprocessor ( DAS ) failure

203

Return air sensor display

204

Charge air sensor display

216

Digital data logger inputs ( DAJ )

234

Check relative humidity sensor

250

Resetting the data recorder clock ( DAS )

251

Check the configuration of the radio expansion card

252

Check the automatic fresh air exchange circuit.